Technical Data
Type | PROFI LIFTER 1200-2,2 | PROFI LIFTER 2000-2,6 | PROFI PULLER 1800-2,2 | PROFI PULLER 3000-2,6 | |
Nominal pressure (required static pressure) | bar | 6 | 6 | 6 | 6 |
Capacity (nominal load for lifting winches) in the last layer | kg | 1200 | 2000 | - | - |
Pulling capacity (nominal load for Pulling winches) in the first layer | kg | - | - | 1800 | 3000 |
Max. number of rope layers | - | 4 | 4 | 4 | 4 |
Max. motor power | kW | 2,2 | 2,6 | 2,2 | 2,6 |
Lifting respectively pulling speed without load² | m/min | 18,5 | 13,0 | 18,5 | 13,0 |
Lifting respectively pulling speed at 80% of the nomainal load² | m/min | 13,3 | 8,8 | 9,8 | 6,0 |
Lifting respectively pulling speed at nominal load² | m/min | 11,6 | 8,0 | 7,0 | 4,6 |
Lowering respectively unwinding speed without load² | m/min | 16,2 | 12,5 | 16,2 | 12,5 |
Lowering speed at nominal load² | m/min | 22,5 | 16,8 | - | - |
Air connection |
| G ¾ | G 1 | G ¾ | G 1 |
Air consumption at nominal load, pulling | m³/min | - | - | 3,4 | 4,0 |
Air consumption at nominal load, lifting | m³/min | 3,9 | 4,5 | - | - |
Air consumption without load, pulling | m³/min | - | - | 4,6 | 5,0 |
Air consumption without load, lifting | m³/min | 4,6 | 5,0 | - | - |
Air consumption without load, lowering | m³/min | 4,2 | 4,3 | - | - |
Air consumption at nominal load, lowering | m³/min | 5,1 | 5,5 | - | - |
Hose size (ø inside, ø outside) | mm | 19/31 | 25/39 | 19/31 | 25/39 |
Rope drum diameter | mm | 240 | 285 | 240 | 285 |
Max. possible rope diameter | mm | 11 | 13 | 11 | 13 |
Minimum breaking force of rope | kN | 58,8 | 98,1 | 53,0 | 88,3 |
Weight (without rope and additional devices) short drum version | kg | 138 | 235 | 138 | 235 |
Weight (without rope and additional devices) long drum version | kg | 158 | 310 | 158 | 310 |
Control length for pendant control | m | 2 | 2 | 2 | 2 |
Noise pressure level without load - lifting or pulling¹ | dB (A) | 88 | 87 | 88 | 87 |
Noise pressure level without load - lowering or unwinding¹ | dB (A) | 90 | 88 | 90 | 88 |
Noise pressure level at nominal load - lifting or pulling¹ | dB (A) | 86 | 85 | 82 | 80 |
Noise pressure level at nominal load - lowering¹ | dB (A) | 92 | 88 | - | - |
¹ measured at 1 m distance according to DIN 45635 part 20
² measured in the first layer with max. rope diameter (further data see section curves)
Dimensions
Dimensions in mm | PROFI LIFTER 1200-2,2 | PROFI LIFTER 2000-2,6 | ||
short drum | long drum | short drum | long drum | |
B1 | 393 | 475 | ||
H1 max. | 540 | 590 | ||
L1 max. | 585 | 785 | 700 | 1100 |
L2 | 216 | 416 | 305 | 705 |
D1 | 240 | 285 | ||
D2 | 350 | 430 | ||
A1 | 295 | 340 | ||
A2 | 312 | 512 | 449 | 849 |
Retaining bolts and nuts (10.9) | ||||
G | M12 | M16 | ||
T [Nm] | 108 | 264 | ||
Dimensions pulling frame
Dimensions in mm | PROFI LIFTER 1200-2,2 | PROFI LIFTER 2000-2,6 | ||
short drum | long drum | short drum | long drum | |
B2 | 460 | 590 | ||
B3 | 407 | 512 | ||
H2 | 80 | 120 | ||
L3 | 344 | 544 | 479 | 879 |
L4 | 244 | 444 | 359 | 759 |
A1 = C1 | 295 | 340 | ||
A2 | 312 | 512 | 449 | 849 |
C2 | 40 | 50 | ||
C3 | 80 | 100 | ||
D3 | 13 | 17 | ||
Performance Data
PROFI LIFTER 1200-2,2 (1 Bm) | Speeds [m/min] | ||||
Lifting | Lowering | ||||
Rope Layer | 1. Layer | 4. Layer | 1. Layer | 4. Layer | |
Load condition [kg] | 0 | 18,9 | 23,5 | 16,3 | 20,2 |
600 | 14,5 | 17,8 | 20,0 | 25,9 | |
1200 | 10,1 | 12,1 | 23,8 | 31,7 | |
1500 | 7,9 | - | 25,6 | - | |
PROFI PULLER 1800-2,2 (1 Bm) | Speeds [m/min] | ||||
Pulling | Unwinding | ||||
Rope Layer | 1. Layer | 4. Layer | 1. Layer | 4. Layer | |
Load condition [kg] | 0 | 18,9 | 23,5 | 16,3 | 20,2 |
600 | 14,5 | 16,7 | - | - | |
1200 | 10,1 | 9,9 | - | - | |
1800 | 5,6 | - | - | - | |
PROFI LIFTER 2000-2,6 (1 Bm) | Speeds [m/min] | ||||
Lifting | Lowering | ||||
Rope Layer | 1. Layer | 4. Layer | 1. Layer | 4. Layer | |
Load condition [kg] | 0 | 12,9 | 16,3 | 12,6 | 15,9 |
1000 | 10,1 | 11,8 | 14,9 | 19,6 | |
2000 | 7,2 | 7,2 | 17,3 | 23,4 | |
2500 | 5,8 | - | 18,5 | - | |
PROFI PULLER 3000-2,6 (1 Bm) | Speeds [m/min] | ||||
Pulling | Unwinding | ||||
Rope Layer | 1. Layer | 4. Layer | 1. Layer | 4. Layer | |
Load condition [kg] | 0 | 12,9 | 16,3 | 12,6 | 15,9 |
1000 | 10,1 | 11,8 | - | - | |
2000 | 7,2 | 7,2 | - | - | |
3000 | 4,4 | - | - | - | |
Characteristic Load Curves PROFI LIFTER 1200-2,2 and PROFI PULLER 1800-2,2
Characteristic Load Curves PROFI LIFTER 2000-2,6 and PROFI PULLER 3000-2,6
Rope Capacities
PROFI LIFTER 1200-2,2 and PROFI PULLER 1800-2,2 | ||||||||||||
Short version |
| Long version | ||||||||||
Rope layers used | Rope diameter | Rope layers used | Rope diameter | |||||||||
mm | 8 | 9 | 10 | 11 | mm | 8 | 9 | 10 | 11 | |||
1st | m | 17,6 | 15,5 | 13,7 | 12,3 | 1st | m | 37,1 | 32,9 | 29,5 | 26,7 | |
1st and 2nd | m | 40,0 | 35,6 | 32,1 | 29,2 | 1st and 2nd | m | 80,2 | 71,6 | 64,7 | 59,1 | |
1st, 2nd and 3rd | m | 63,8 | 57,1 | 51,7 | 47,4 | 1st, 2nd and 3rd | m | 126,0 | 113,0 | 102,6 | 94,2 | |
1st, 2nd, 3rd and 4th | m | 88,9 | 79,9 | 72,8 | 66,9 | 1st, 2nd, 3rd and 4th | m | 174,3 | 157,0 | 143,2 | 131,8 | |
Recommended rope diameter: 9 up to 10 mm
Rope diameter for grooving rope drums: 10 mm
PROFI LIFTER 2000-2,6 and PROFI PULLER 3000-2,6 | ||||||||||||
Short version |
| Long version | ||||||||||
Rope layers used | Rope diameter | Rope layers used | Rope diameter | |||||||||
mm | 10 | 11 | 12 | 13 | mm | 10 | 11 | 12 | 13 | |||
1st | m | 24,3 | 21,9 | 19,9 | 18,2 | 1st | m | 61,4 | 55,7 | 51,0 | 47,0 | |
1st and 2nd | m | 54,4 | 49,5 | 45,5 | 42,0 | 1st and 2nd | m | 131,0 | 119,6 | 110,2 | 102,1 | |
1st, 2nd and 3rd | m | 86,4 | 79,0 | 72,9 | 67,7 | 1st, 2nd and 3rd | m | 205,1 | 188,0 | 173,8 | 161,7 | |
1st, 2nd, 3rd and 4th | m | 120,3 | 110,5 | 102,3 | 95,4 | 1st, 2nd, 3rd and 4th | m | 283,6 | 260,8 | 241,8 | 225,7 | |
Recommended rope diameter: 12 mm Rope diameter for grooving rope drums: 13 mm